Fill out the data sheet, send it to
mail sales@rogeng.ru and we will give an accurate estimate of the cost of your project
The flow meters are a part of oil treatment plants, preliminary water gathering stations and other above-ground facilities.
Oil measuring devices ensure:
Designation |
Dimensions |
||||||
SIKN – 0,10 | SIKN – 0,25 | SIKN – 0,50 | SIKN - 100 | SIKN - 200 | SIKN - 300 | SIKN - 400 | |
Flow rate, kg/hour: Nominal range Maximum flow rate |
Up to 82 108 |
Up to 1090 2180 |
Up to 3400 6800 |
Up to 13600 27200 |
Up to 43550 87100 |
Up to 136080 272160 |
Up to 409000 545500 |
Nominal pressure, MPa |
1,6, 2,5, 4,0, 6,3 |
||||||
Ambient temperature, оC |
+5-+50 | ||||||
Media viscosity, cSt max. |
300 | ||||||
Density, kg/m3 |
1100 |
||||||
Water content, % max. |
90 |
||||||
Operating medium |
oil, oil emulsion |
||||||
Operating mode |
permanent | ||||||
Limits of the relative permissible measurement accuracy: | |||||||
Crude oil masses | ± 2,5% | ||||||
Crude oil masses excluding water, with the water content of the crude oil in volume fractions: | up to 70% - ±6%; | ||||||
from 70% up to 95% - ± 15% | |||||||
Service life, years | 15 |