Horizontal flare units (GFU) with remote ignition and control are intended for flaring (utilization by combustion) of gases, vapors and liquids during emergency, continuous and periodic discharges at field production and preparation of oil, gas and water in oil&gas fields, enterprises of chemical, petrochemical and oil refining industries.
Climatic modification and environmental class as per GOST 15150.
a) horizontal flare unit GFU-V-50-HL1 TU 28.99.39-005-20676863-2017, where:
b) horizontal flare unit GFU-N-650-HL1 TU 28.99.39-005-20676863-2017, where:V- type of discharge - hydrocarbon gases and high-pressure vapors;
50 - flare gas consumption, thousand nm3/h;
HL1 - climatic modification and environmental class.
c) horizontal flare unit GFU- ZH-3-HL1 TU 28.99.39-005-20676863-2017, where:N - type of discharge - hydrocarbon gases and low-pressure vapors;
650 - flare gas consumption, thousand nm3/day;
HL1 - climatic modification and environmental class.
d) horizontal flare unit GFU-ZHU-8-HL1 TU 28.99.39-005-20676863-2017, where:ZH — type of discharge — liquid non-combustible industrial effluents;
3 - utilized industrial effluents flow rate, m3/h;
HL1 - climatic modification and environmental class.
e) combined horizontal flare unit GFU-ZH-3-L-75-U1 TU 28.99.39-005-20676863-2017, where:ZHU - type of discharge - liquid hydrocarbons;
6 - consumption of recycled liquid hydrocarbons, m3/h;
HL1 - climatic modification and environmental class.
Depending on purpose and type of discharges, GFU are divided into the following types:ZH and N - type of discharge - liquid non-combustible industrial effluents and hydrocarbon gases and low-pressure vapors;
3 - industrial effluents flow rate, m3/h;
75 - hydrocarbon gases and low-pressure vapors flow rate, thousand nm3/day;
U1 - climatic modification and environmental class.
GFU-V is a horizontal high-pressure flare unit
GFU-V is a horizontal high-pressure flare unit designed for flaring of hydrocarbon gases with discharge excess pressure of 0,2 MPa or more (gas from initial stages of oil separation, purge gases from gas fields during blowdown of flowlines, emergency depressurizing);
GFU-N is a horizontal high-pressure flare unit
GFU-N is a horizontal high-pressure flare unit designed for flaring of hydrocarbon gases with discharge excess pressure less than 0,2 MPa (gas from terminal stages of oil separation, safety valves and purge lines discharges).
GFU-ZH is a horizontal flare unit
GFU-ZH is a horizontal flare unit for thermal utilization (neutralization, treatment) of non-combustible industrial effluents (by contact heating and vaporization in flare simultaneously with flaring of dissolved organic matter).
GFU - ZHU is a horizontal flare unit
GFU - ZHU is a horizontal flare unit for flaring of liquid hydrocarbons (oil, gas condensate) and other combustible liquids. Combined GFU for utilization of various types of discharges are available for manufacturing, for example: GFU-V-N, GFU-ZH-V-N, GFU-ZH-N, GFU-ZH-V;