Mobile preliminary water discharge unit (PKIOS)

Mobile preliminary water discharge unit (PKIOS)

Back Download data sheet
Download data sheet
Fill out the data sheet, send it to
mail sales@rogeng.ru and we will give an accurate estimate of the cost of your project
Download data sheet
CONFORMITY CERTIFICATE

CERTIFICATE OF CONFORMITY TO THE SYSTEM OF VOLUNTARY CERTIFICATION INTERGAZSERT

Mobile units for survey, gathering and processing of wells are designed for automated measuring of well flow rate at various wellhead pressures, as well as separation of oil from gas and water, followed by filling in tank trucks, feeding into the oil&gas gathering system, flare recycling, gas treatment for own use supply to the gas gathering system or electricity generation on site.

Equipment composition:

PKIOS equipment is made in block design on a frame base. 

Parts of mobile units can be installed:
  • on skid
  • on chassis
  • on a semitrailer

Overall view

Advantages of mobile units in comparison with capital construction facilities 

  • flexible system of parameters selection and equipment package;
  • full factory readiness of the complex unit;
  • compact dimensions and aesthetic appearance;
  • mobility and ease of movement;
  • reduced terms of mounting/dismounting;
  • ease of assembly interunit pipes by the quick-release connect;
  • operation in remote maintenance mode without the constant presence of personnel.

Technical specifications 

Work environment

Products of oil and gas, gas condensate wells (oil, gas, condensate, produced water)

Productivity m3/d

- for fluid, m3/day

- for gas

 

1….500*

1000….500 000

Design pressure (at the inlet of the PKIOS), MPa

1,6; 2,5; 4,0; 6,3; 10,0; 16,0; 35,0

The composition of the well product:

- hydrogen sulphide H2S, % vol.

- carbon dioxide CO2, %

 

to 6*

to 2,5*

accuracy of liquid mass flow measurement, mass.

±2,5

accuracy of gas volume flow measurement, %

±5

Power supply to electrical circuits:

current

voltage, V

current frequency, Hz

 

alternating

380

50

Ambient temperature, 0C

from -60 to +50

Product

repairable

Estimated mean time between failures, hours

Not less than 10 000

Average life before overhaul, h

Not less than 43 000

Service life, not less than (years)

20