Modernized water settlers (OVM)

Modernized water settlers (OVM)

Back Download data sheet
Download data sheet
Fill out the data sheet, send it to
mail sales@rogeng.ru and we will give an accurate estimate of the cost of your project
Download data sheet
Modernized water settlers are designed to separate oilfield water from oil products and mechanical impurities to provide required quality of the product for pumping into reservoir-pressure maintenance.

Overall view

CONFORMITY CERTIFICATE

Equipment configuration  

Modernized oilfield water settlers are available in the following configuration: horizontal tank, set of instrumentation and automation equipment, internal settlers for water treatment and an upper cap for collecting and draining of recovered oil.

Dimensions and technological volume are determined depending on capacity, physical-chemical properties of oil, oilfield water, mode of operation and quality requirements for water treatment.

Internal anti-corrosion coating of equipment is applicable as protection against corrosion. Settlers designed for operating environment containing corrosive components (including hydrogen sulphide) are packages with internal equipment made of stainless molybdenum steel.

The automation system provides measurement, control and archiving of the following technological parameters: temperature, pressure, phase separation level "oil- water".

Technical specifications

Motive fluid

oilfield water

Design pressure, MPa

0,6; 1,0; 1,6; 2,5

Capacity, m3/day                 1200-10 000

Content in oilfield water at inlet, mg/l

-  oil                                                                                     up to 1000

-  mechanical impurities

up to 200

Content in oilfield water at outlet, mg/l    

-  oil

no more than 40

-  mechanical impurities

no more than 40

Ambient temperature, 0С

from -60 to +50

Service life, not less than (years)

20


Reference designation sample of OVM (OV) for ordering or other documentation:

Modernized water settler (OVM) 50-1,6-T-I-P-HL1

TU 28.99.39-008-20676863-2017, where

      50 – volume, m3;

      1,6 – design pressure, MPa;

      H - heat treatment;

      I - bracket for mounting insulation;

      P -internal anti-corrosion coating;

     HL1 - climatic modification.